MN2-A-03-615-1-2CC-B-C [Carling Technologies]
Magnetic Circuit Breaker,;型号: | MN2-A-03-615-1-2CC-B-C |
厂家: | Carling Technologies |
描述: | Magnetic Circuit Breaker, |
文件: | 总24页 (文件大小:3208K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
M-
iesSeries
M-Ser
CIRCUIT BREAKER
The M-Series is a low cost, miniature, hydraulic-magnetic circuit breaker which features a compact, space saving
design, front panel snap-in mounting and a vertically mounted parallel pole configuration. It features various
styling options to maximize your design flexibility. Choices include rocker, illuminated rocker, paddle and
baton style handle actuators, push-to-reset and push-pull pushbutton actuators, as well as Visi-Rocker two color
actuators. Our exclusive Rockerguard bezel helps prevent inadvertent actuation and a wiping contact mechanism
assures long-term reliability.
The M-Series circuit breakers are available with 1, 2 or parallel poles, 0.02 to 50 amp ratings, and 125 and
250VAC or 80VDC versions. With over 16 different time delays, 5 terminal styles, a variety of panel hardware,
various colors, and legend imprinting, it assures suitability for most any application design.
Resources:
Download 3D CAD Files
IGS
STP
Product Highlights:
Parallel pole configuration fits in one rack unit
Typical Applications:
Telecom/Datacom
MIL-PRF-55629
Transportation
MIL STD 202 compliant
Marine
MIL-PRF-39019F ingress protection
Generators
Sealed toggle actuator
Power Supplies
Compact design
Medical Equipment
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
M-Series Circuit Breaker - General Specifications
2
Electrical
Mechanical
Maximum Voltage
125/250 VAC 50/60 Hz, 80 VDC
(See Rating Tables.)
Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00 thru 15.0
in 1 amp increments, 18.0, 20.0,
25.0, 30.0. Other ratings available
- see Ordering Scheme.
Endurance
10,000 ON-OFF operations @ 6
per minute with rated Current and
Voltage.
All M-Series Circuit Breakers will
trip on overload, even when
actuator is forcibly held in the ON
position.
Current Ratings
Trip Free
Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res)
28VDC, 4A (Ind.) 28VDC, 0.25A
Trip Indication
The actuator moves positively
to the OFF position when an
overload causes the circuit
breaker to trip.
80VDC (Res) (silver contacts),
0.1A 125VAC (gold contacts).
Insulation Resistance
Dielectric Strength
Minimum of 100 Megohms at 500
VDC.
Physical
Number of Poles
Internal Circuit Configs.
1 or 2
Series with or without
Auxiliary Switch.
Switch Only with or without
Auxiliary Switch.
Approximately 30 grams/pole
(Approximately 1.07 ounces/pole)
See Ordering Scheme
UL, CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals. M-Series
Circuit Breakers comply with the
8mm spacing and 3750 V 50/60Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, per
Weight
Standard Colors
Environmental
Publications IEC 380, 435, 950,
EN 60950 and VDE 0805.
Designed in accordance with requirements of specification
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
MIL PRF-55629 & MIL-STD-202G as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Cond. I. Instantaneous
curves tested at 80% of rated
current.
Withstands 0.060” excursion
from 10-55 Hz, and 10 Gs 55-500
Hz, at rated current per Method
204C, Test Condition A.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
CURRENT
(AMPS)
TOLERANCE
(%)
Vibration
0.10 - 20.0
20.1 - ꢀ0.0
2ꢀ
3ꢀ
Instantaneous curves tested at
80% of rated current.
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-
98% RH.
Moisture Resistance
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Thermal Shock
Pulse Tolerance Curves
Operating Temperature -40° C to +85° C
Chemical Resistance Only the outside surfaces of the
case and the handles may be
cleaned with detergents or
alcohol. Organic (hydrocarbon
based) solvents are not
recommended because they
attack plastics. Caution should
be taken when solvents are used
to clean and remove flux from
terminals. Lubricants should not
be introduced into the handle/
bushing openings
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - General Specifications |
3
Electrical Tables
Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary
Protector.
M-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Voltage
Current Rating
Short Circuit Capacity (Amps)
UL / CSA
With Backup Without Backup
Application Codes
UL CSA
Circuit
Configuration
Poles
Max
Rating
Full Load
Amps
General
Purpose Amps
Breaking
Frequency Phase
Fuse
---
---
---
---
Fuse
1000
1000
1000
1000
1000
0.02 - 1ꢀ
---
0.02 - 7.ꢀ
0.02 - 1ꢀ
---
---
1ꢀ.1 - 2ꢀ
---
---
1ꢀ.1 - 2ꢀ
1
1
1
2
2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
32
DC
DC
DC
---
---
---
ꢀ0 2
6ꢀ
---
0.02 - 1ꢀ
---
0.02 - 1ꢀ
---
0.02 - 1ꢀ
---
0.02 - 1ꢀ
---
1 ꢁ 30
0.02 - 12
---
0.02 - 1ꢀ
---
---
1ꢀ.1 - 30
---
1ꢀ.1 - 2ꢀ
---
1ꢀ.1 - 30
---
1ꢀ.1 - 30
---
---
12.1 - 18
---
1ꢀ.1 - 30
---
1
1
2
2
1
1
1
1
1
1
1
2
2
2
---
---
ꢀ000 3
ꢀ000 3
---
---
---
---
---
---
1000 4
---
---
1000
1000
---
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
6ꢀ 1,2
6ꢀ
DC
DC
DC
---
---
---
TC1, 2, OL1, C1
TC1, 2, OL0, C1
TC1, 2, OL1, C1
TC1, 2, OL0, C1
---
600
600
1000
1000
360
1000
---
1000
1000
360
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
Series
80 1
12ꢀ
ꢀ0 / 60
1
TC1, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC3, OL1, U3
2ꢀ0 2
2ꢀ0
ꢀ0 / 60
ꢀ0 / 60
1
1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
2ꢀ0
ꢀ0 / 60
1
1 ꢁ 30
---
TC1, OL1, U2
TC3, OL1, U3
Notes:
1
2
3
4
Polarity Sensitive
Available only with Special Catalog Number. Consult Factory.
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
M-SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS
Voltage
Current Rating
Short Circuit Capacity (Amps)
Application Codes
UL CSA
UL / CSA
With Without
VDE / TUV
With Without
Backup Backup Backup Backup
Circuit
Configuration
Poles
General
Purpose
Amps
Max
Rating
Full Load
Amps
Breaking
Frequency Phase
Fuse
---
Fuse
1000
1000
1000
1000
1000
Fuse
3000
3000
3000
3000
3000
Fuse
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
0.02 - 1ꢀ
---
0.02 - 7.ꢀ
0.02 - 1ꢀ
---
---
1ꢀ.1 - 2ꢀ
---
---
1ꢀ.1 - 2ꢀ
1
1
1
2
2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
32
DC
DC
DC
---
---
---
---
---
---
---
ꢀ0 2
6ꢀ
0.02 - 1ꢀ
---
0.02 - 1ꢀ
---
0.02 - 1ꢀ
1 ꢁ 1ꢀ
0.02 - 12
0.02 - 20
1 ꢁ 12
---
1ꢀ.1 - 30
---
1ꢀ.1 - 30
---
2
2
1
1
1
1
1
2
1
ꢀ000
ꢀ000
---
---
---
---
---
---
---
---
---
3000
3000
---
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
ꢀ00
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
6ꢀ 3
80 1
12ꢀ
DC
DC
---
---
1
Series
600 4
600 4
1000
360
1000
1000
360
---
3000
3000
3000
3000
3000
ꢀ0 / 60
---
---
---
---
TC1, OL1, U2
TC3, OL1, U3
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
2ꢀ0
ꢀ0 / 60
1
TC1, OL1, U2
TC3, OL1, U3
Notes:
1
2
3
4
5
Polarity Sensitive
Available only with Special Catalog Number. Consult Factory.
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
TUV only, not VDE
Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a
Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps,
and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per
EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
M-Series Circuit Breaker - General Specifications
Electrical Tables
Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications
Equipment.
M-SERIES TABLE C: UL489A Listed
(Communications Equipment - Polarity Sensitive)
Voltage
Interrupting Capacity (Amps)
Without Backup Fuse
Current Rating
General Purpose
Amps
Circuit
Configuration
Poles
Breaking
Max
Rating
Frequency
UL489A
TUV
80
6ꢀ 1
80
DC
DC
DC
0.02 - 30
0.02 - 30
0.10 - 30
1
1
1
600
1000
600
---
---
600
Series
Notes:
1.
Available only with Special Catalog Number
Table D: Lists UL489A Listed configurations and performance capabilities for use in Communications Equipment.
M-SERIES TABLE D: Parallel Pole Construction UL489A Listed
(Communications Equipment - Polarity Sensitive)
Voltage
Interrupting Capacity (Amps)
Current Rating
General Purpose
Amps
Circuit
Poles
Without Backup Fuse
Max
Configuration
Breaking
Frequency
Rating
UL489A
600
1000
80
6ꢀ 1
DC
DC
31 - ꢀ0
31 - ꢀ0
2
2
Series
Notes:
1.
Available only with Special Catalog Number
Agency Certifications
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
UL Recognized
UL Standard 1077
CSA Accepted
Component Recognition Program
as Protectors, Supplementary
(Guide CCN/QVNU2, File E75596)
CSA Standard C22.2 No. 235
EN60934, VDE 0642 under File
10537
UL Listed
UL Standard 489A
VDE Certified
TUV Certified
Communications Equipment
(Guide CCN/DITT, File E189195)
EN60934, under License No.
R9671109
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Parallel Pole Rocker - Ordering Scheme |
5
M E 2 P
650 5 A 1 2 B T
D2
8
9
10
Legend
11
Bezel
Color
12
Agency
Approval
1
2
3
4
5
6
7
Illumination Actuator
Color &
Series
Actuator Poles
Circuit
Frequency
& Delay
Current
Rating
Terminal
Legend
7 TERMINAL
1 SERIES
M
A
5
Push in Stud
10-32 Screw (Bus Type)
2 ACTUATOR
Single Color
Two Color Visi
Single Color Translucent
8 ILLUMINATION
Non-Illuminated
A
B
Angled
Flat
D
E
Indicate ON
Indicate OFF
F
Angled
Flat
G
A
Non-Illuminated
9 ACTUATOR COLOR & LEGEND
1
Actuator Visi
Legend
Black
White
White
White
White
Black
Black
Black
1
2
3
4
5
6
7
8
White
Black
Red
Green
Blue
Yellow
Gray
Orange
10 LEGEND
2
3
6
7
ON - OFF Vertical
ON - OFF Horizontal
Dual Vertical
3 POLES
Two
2
Dual Horizontal
2
4 CIRCUIT/AUXILIARY SWITCH
P
Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
11 BEZEL COLOR
A
B
G
1
2
7
White without Rockerguard
Q
Black without Rockerguard
Gray without Rockerguard
White with Rockerguard
Black with Rockerguard
Gray with Rockerguard
R
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium
12 AGENCY APPROVAL
UL 489A Listed
T
6 CURRENT RATING (AMPERES)
CODE
631
635
640
645
650
AMPERES
31.000
35.000
40.000
45.000
50.000
Notes:
1
2
Reminder of Rocker same color as Visi
Aux Switch only available with screw terminals
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
M-Series Circuit Breaker - Parallel Pole - Handle / Push Button - Ordering Scheme
M M 2 P
650 5 1 B B B T
D2
8
9
10
Legend
Plate/
11
Brushing
Color
12
Agency
Approval
1
2
3
4
5
6
7
Actuator
Color
Front
Panel
Series
Actuator Poles
Circuit
Frequency
& Delay
Current
Rating
Terminal
Hardware Marking
9 FRONT PANEL HARDWARE
Handle
1 SERIES
M
A
B
C
D
E
F
G
H
J
No outer Panel Hardware
Knurled Nut, Bright Nickel
Knurled Nut, Bright Nickel with Locking Ring
Knurled Nut, Black
Knurled Nut, Black with Locking Ring
Panel Dress, Bright Nickel
Panel Dress, Bright Nickel with Locking Ring
Panel Dress, Black
2 ACTUATOR
M
T
Paddle
Push-Pull
3 POLES
Two
2
Panel Dress, Black with Locking Ring
Push Button
1
1
2
No outer Panel Hardware
Knurled Nut, Bright Nickel
4 CIRCUIT/AUXILIARY SWITCH
P
Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
Q
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate
R
B
C
ON - OFF Vertical
ON - OFF Horizontal
Push-Pull Actuator Legend Plate
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium
2
3
4
Rated Amps Horizontal
Rated Amps Line Side Down
Rated Amps Line Side Up
6 CURRENT RATING (AMPERES)
11 BUSHING COLOR
Black
CODE
631
635
640
645
650
AMPERES
31.000
35.000
40.000
45.000
50.000
B
12 AGENCY APPROVAL
T
UL 489A Listed
Notes:
1
Aux Switch only available with screw terminals
7 TERMINAL
A
5
Push in Stud
10-32 Screw (Bus Type)
8 ACTUATOR COLOR & LEGEND
Handle
Push Button
1
2
3
4
5
6
7
8
White
Black
Red
Green
Blue
Yellow
Gray
Orange
A
B
C
D
E
F
White
Black
Red
Green
Blue
Yellow
Gray
G
H
Orange
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Parallel Pole - Dimensional Specifications |
7
Dimensional Specifications: in. [mm]
PARALLEL POLE TERMINAL OPTIONS
PUSH-IN STUD
10-32 SCREW W/ BUS BAR
.652 [16.56]
.838 [21.29]
1.125 [28.58]
.912 [23.16]
.154 [3.91]
1.000 [25.4]
.393 [9.97]
1.000 [25.4]
.100 [2.54]
.750 [19.05]
ROCKER ACTUATOR DETAIL
INDICATE "ON" (VISI-ON)
.370 [9.40] MAX.
±.020
[±.508]
±.020
[±.508]
1.394 [35.41]
1.530 [38.86]
1.304 [33.12]
LINE
1.375 [34.93]
OFF
ON
1.560 [39.62]
.970 [24.64]
1.125 [28.58]
LOAD
.625 [15.88]
.100 [2.54]
.400 [10.16]
ROCKERGUARD CONFIGURATION
INDICATE "OFF" (VISI-OFF)
& SINGLE COLOR
±.020 ±.508
.305 [7.75]
±.020
.675 [17.±1.540]8
LOAD
LINE
LOAD
LINE
ON
ON
±.020 ±.508
1.050 [26.67]
OFF
OFF
PANEL CUT - OUT DETAIL (ROCKER)
DOUBLE POLE
DIM. A
PANEL
THICKNESS
+.005 +.13
-.000 -.00
.062 [1.57] 1.385 [35.18]
.093 [2.36] 1.420 [36.07]
.125 [3.18] 1.460 [37.08]
DIM. A
±.005 ±.13
1.139 [33.76]
Notes:
1
2
3
4
5
All dimensions are in inches [millimeters].
Tolerance ±.010 [.25] unless otherwise specified.
Dimensions apply to both rocker styles.
I-o, on-off or dual legends available for vertical or horizontal mounting.
Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
M-Series Circuit Breaker - Parallel Pole - Dimensional Specifications
Dimensional Specifications: in. [mm]
PADDLE ACTUATOR STYLE
PUSH-PULL ACTUATOR STYLE
1.484
1.395
1/2-32 THD.
3/8" 8-32 THD.
12°
ON
ACTUATOR COLOR
VISIBLE IN OFF
POSITION ONLY
±.030 ±.76
OFF
FLAT
12°
.500 [12.70] OFF (SHOWN)
.400 [10.16]
FLAT
±.030 ±.76
±.030 ±.76
±.030 ±.76
.470 [11.94]
.280 [7.11] ON
.500 [12.70]
MOUNTING DETAILS
PANEL HARDWARE
MOUNTING DETAILS
.494
[12.55]
.098
[2.49]
+.010
-.000
+.25
+.010
-.000
+.25
-.000
-.000
+.010 +.25
-.00
.500 DIA [Ø12.70]
.500 DIA [Ø12.70]
.-3.07050 [9.53]
±.002 ±.05
.162 [4.11]
DIA
+.25
-.000
PUSH-PULL,
PUSH TO RESET
+.010
-.000
±.005 [±.13]
HEX NUT
±.002 [±.050]
.222 [5.64]
.125 DIA [Ø3.18]
.355 [9.02]
.544[13.82]
WITH LOCKING RING
WITHOUT LOCKING RING
.156
[3.56]
.625 [15.87] DIA
.534
[13.56]
.078
[1.98]
LEGEND PLATES
SNAP-IN BUSHING
.435 [11.05] DIA
.025 [.64]
.632 DIA [Ø16.05]
.340 [8.64]
PANEL DRESS NUT
0N
O
F
F
O
N
1.025 [26.04]
BUTTON MARKING ORIENTATION
0FF
LINE
B
C
LEGEND
CODE:
20
LINE
20
20
PANEL HARDWARE
LINE
.625 [15.88]
.125 [3.18]
.680 DIA [Ø17.27]
.180 [4.57]
MARKING
CODE:
2
3
4
.110QC AUXILIARY SWITCH TERMINALS
PANEL DRESS NUT
HEX NUT
.680 DIA [Ø17.27]
.125 [3.18]
.105 [2.67]
.342 [8.69]
.031 [.79]
.683 DIA [Ø17.27]
KNURLED NUT
LOCKING RING
Notes:
1
2
3
4
5
All dimensions are in inches [millimeters].
Tolerance ±.010 [.25] unless otherwise specified.
Dimensions apply to both rocker styles.
I-o, on-off or dual legends available for vertical or horizontal mounting.
Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Handle/Pushbutton UL Recognized - Ordering Scheme |
9
M M 1 B 34 260 1 1 B B C B
8
9
10
11
Bushing
Color
12
Agency
Approval
1
2
3
4
5
6
7
Actuator
Color
Front Panel Legend
Hardware Plate
Series
Actuator
Poles
Circuit
Frequency
& Delay
Current
Rating
Terminal
1 SERIES
M
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
1
2 ACTUATOR
Handle
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
M
Paddle
N
Baton
Push Button
Push-Pull
T
U
Push To Reset
Push Button with
Snap-In Mounting
V
Push-Pull
W
Push To Reset
9
3 POLES
1
One
2
Two
7 TERMINAL
2
11
12
4 CIRCUIT
1
2
3
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with Upturned Lugs
Screw 8-32 (Bus Type)
A
P
Push-In Stud
Printed Circuit Board
10
10
without Auxiliary Switch
(
)
A
B
Switch Only no coil , Maintained Contacts
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
5
8 ACTUATOR COLOR & LEGEND
Gloss Handle
M
P
Q
R
S
T
Series Trip (Current) Aux Switch .110 QC x .020 QC
Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Switch Only, Maintained Contacts .058 Dia, Round Q.C.
Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
3
3,4
3,13
3
3,4
3,13
Push-Button
Actuator Color
1
2
3
4
5
6
8
A
B
C
D
E
F
White
Black
Red
Series Trip (Current)
Series Trip (Current)
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
Green
Blue
U
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
Yellow
Orange
with Auxiliary Switch, Gold Contacts
H
3,4
3,13
3,4
2
3
4
5
9
Switch Only, Maintained Contacts .058 Dia, Round Q.C.
Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
Series Trip (Current)
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
Series Trip (Current) Aux Switch .110 QC x .020 QC
.058 Dia, Round Q.C.
6
9 FRONT PANEL HARDWARE
3,13
Handle
A
Push-Button
1
No outer Panel Hardware
Knurled Nut
Bright nickel
B
C
D
E
2
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
12 DC Short
14 DC Medium
20 50/60Hz Instantaneous
22 50/60Hz Short
Bright nickel with locking ring
Black
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
92 DC, 50/60Hz Short, Hi-Inrush
94 DC, 50/60Hz Medium, Hi-Inrush
Black with locking ring
Panel Dress Nut
Bright nickel
F
G
H
J
Bright nickel with locking ring
Black
Black with locking ring
24 50/60Hz Medium
30 DC, 50/60Hz Instantaneous
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
Full Load Amp
Tungsten Lamp
General Purpose Amps
Rating
Voltage
Rating
Poles
A
B
C
D
E
No Legend Plate
ON - OFF Vertical
ON - OFF Horizontal
I - O Vertical
Choose
Current Coil
Rating Code
Choose
Current Coil
Rating Code
Breaking
Max
Max
Amps
Max Choose Current Max
Amps Coil Rating Code Amps
Frequency Phase
Rating
32
ꢀ0
6ꢀ
DC
DC
DC
-
-
1
1
1
1
1ꢀ
-
61ꢀ
-
2ꢀ
62ꢀ
-
-
-
-
1
1
2
1
1
2
I - O Horizontal
7.ꢀ Consult Factory
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1ꢀ
1ꢀ
12
1ꢀ
61ꢀ
61ꢀ
612
61ꢀ
2ꢀ
2ꢀ
-
62ꢀ
62ꢀ
-
1ꢀ
-
-
1
2
3
4
No Marking
Rated Amps Horizontal
Rated Amps Line Side Down
Rated Amps Line Side Up
12ꢀ ꢀ0/60Hz
2ꢀ0 ꢀ0/60Hz
2ꢀ0 ꢀ0/60Hz
61ꢀ
-
-
2ꢀ
62ꢀ
-
Push-to-Reset Actuator Button (Actuator Styles U & W)
1
No Marking
Notes:
1
2
3
One actuator is located in the center of each multi-pole breaker. Actuator codes V & W
limited to single pole breakers only.
Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits,
select Current Coil Rating from the above chart:
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only
circuits. Not available with back connect screw or push-in stud terminals.
Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated)
and 60983-2 (tin plated).
7
11 BUSHING COLOR
Black
B
8
12 AGENCY APPROVAL
4
C
D
E
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
5
6
Actuator color is only visible in the OFF position on Push-Pull actuators.
All units except snap-in mounting have one hex nut installed on bushing for use behind
the panel.
7
8
Other colors available. Consult factory.
TUV 20A, VDE 15A. UL Recognized and CSAAccepted to 30 amps.
Screw Terminals or Push-in Stud recommended above 20 amps.
30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
9
10 Screw Terminals are VDE certified only with use of ring terminal attached to wire.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
M-Series Circuit Breaker - Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme
M M 1 B 14 620 1 1 B B B J
8
9
10
11
Bushing
Color
12
Agency
Approval
1
2
3
4
5
6
7
Actuator
Color
Front Panel Legend
Hardware Plate
Series
Actuator
Poles
Circuit
Frequency
& Delay
Current
Rating
Terminal
4
7 TERMINAL
1 SERIES
10
11
M
1
2
3
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with Upturned Lugs
Screw 8-32 (Bus Type)
A
P
Push-In Stud
Printed Circuit Board
1
2 ACTUATOR
Handle
5
8 ACTUATOR COLOR & LEGEND
Gloss Handle
M
Paddle
Push-Button
Actuator Color
White
N
Baton
1
2
3
4
5
6
8
A
B
C
D
E
F
Black
Push Button
Push-Pull
Red
T
Green
8
U
Push To Reset
Blue
Yellow
Orange
Push Button with
Snap-In Mounting
H
8
V
Push-Pull
W
Push To Reset
6
9 FRONT PANEL HARDWARE
Handle
A
Push-Button
1
No outer Panel Hardware
Knurled Nut
3 POLES
1
One
Bright nickel
B
C
D
E
2
Bright nickel with locking ring
Black
4 CIRCUIT
without Auxiliary Switch
Black with locking ring
Panel Dress Nut
Bright nickel
B
Series Trip (Current)
F
G
H
J
with Auxiliary Switch, Silver Contacts Terminal Type:
Bright nickel with locking ring
Black
M
S
T
Series Trip (Current) Aux Switch .110 QC x .020 QC
3
3,4
3,13
Series Trip (Current)
Series Trip (Current)
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
Black with locking ring
U
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
2,3
3,12
4
5
9
Series Trip (Current)
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
Series Trip (Current) Aux Switch .110 QC x .020 QC
.058 Dia, Round Q.C.
A
B
C
D
E
No Legend Plate
ON - OFF Vertical
ON - OFF Horizontal
I - O Vertical
5 FREQUENCY & DELAY
10 DC Instantaneous
12 DC Short
I - O Horizontal
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
Push-Pull Actuator Button Cap (Actuator Styles T & V)
8
1
2
3
4
No Marking
14 DC Medium
Rated Amps Horizontal
Rated Amps Line Side Down
Rated Amps Line Side Up
6 CURRENT RATING (AMPERES)
Push-to-Reset Actuator Button (Actuator Styles U & W)
CODE
AMPERES
8
1
No Marking
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611
711
11.000
11.500
7
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
11 BUSHING COLOR
Black
B
9
12 AGENCY APPROVAL
J
M
N
T
UL489A Listed, TUV Certified
UL Recognized, CSA Accepted
UL Recognized, TUV Certified
UL489A Listed
1
2
One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited
to single pole breakers only.
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch
mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits.
Not available with Back Connected Screw or Push-in Stud terminals.
Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and
60983-3 (tin plated).
3
4
5
6
7
8
9
Screw terminals or Push-in Stud recommended above 20 amps.
Actuator color is only visible in the OFF position on Push-Pull actuators.
All units have one hex nut installed on bushing for use behind the panel.
Other colors available. Consult factory.
Not available with UL489A Listed breakers.
UL Recognized, CSAAccepted and UL Listed to 30 amps.
10 Terminal code A available with circuit codes A & B only.
11 Printed circuit board available with UL recognized approval only.
12 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams |
11
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
M-Series Circuit Breaker - Handle – PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Handle - Dimensional Specifications |
13
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
14
M-Series Circuit Breaker - Pushbutton – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Pushbutton – Dimensional Specifications |
15
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
Available with Push-Pull or Push-to-Reset Actuators
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
16
M-Series Circuit Breaker - Push-Pull – PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme |
17
M G 2 B 34 620 1 H C 6 7 C
8
9
10
Legend
11
12
Agency
Approval
1
2
3
4
5
6
7
Illumination Actuator
Color
Bezel Color
Series
Actuator
Poles
Circuit
Frequency
& Delay
Current Rating
Terminal
1 SERIES
M
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611
711
11.000
11.500
1
2 ACTUATOR
Non-Illuminated
single color
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
Two Color
Visi-Rocker
illuminated
single color
A
B
Angled
Flat
D
E
Indicate ON
Indicate OFF
F
Angled
Flat
G
12
630 30.000
3 POLES
1
One
2
Two
7 TERMINAL
2
14
15
4 CIRCUIT
1
2
3
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with Upturned Lugs
Screw 8-32 (Bus Type)
A
P
Push-In Stud
Printed Circuit Board
10
10
without Auxiliary Switch
(
)
A
B
Switch Only no coil , Maintained Contacts
Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
8 ROCKER ILLUMINATION
Non-illuminated
M
P
Q
R
S
T
Series Trip (Current) Aux Switch .110 QC x .020 QC
3
3,4
3,16
3
3,4
3,16
A
Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Switch Only, Maintained Contacts .058 Dia, Round Q.C.
Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
5
8
Neon
Neon
B
Green Glow
C
Green
G
H
J
without resistor, 120VAC/250VAC
7, 8
LED
Red
D
E
F
Amber
Series Trip (Current)
Series Trip (Current)
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
without resistor
K
L
M
with resistor, 4-8 VDC
with resistor, 9-16 VDC
U
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
3,4
3,16
3,4
2
3
4
5
9
Switch Only, Maintained Contacts .058 Dia, Round Q.C.
Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 ACTUATOR & LEGEND COLOR
Series Trip (Current)
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
Series Trip (Current) Aux Switch .110 QC x .020 QC
.058 Dia, Round Q.C.
3,16
Solid Color
Actuator
White
Black
Red
Green
Blue
Yellow
Gray
Orange
Legend
1
Black
White
White
White
White
Black
Black
Black
2
3
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
12 DC Short
14 DC Medium
20 50/60Hz Instantaneous
22 50/60Hz Short
4
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
92 DC, 50/60Hz Short, Hi-Inrush
94 DC, 50/60Hz Medium, Hi-Inrush
5
6
7
8
6
Visi-Rocker
Visi & Legend (remainder of rocker same color as bezel)
1
White
Black
Red
Green
Blue
24 50/60Hz Medium
30 DC, 50/60Hz Instantaneous
2
3
4
5
6
Yellow
Gray
7
8
Orange
8
Illuminated
Actuator
Legend
White
White
White
White
White
Black
A
B
C
D
E
F
Clear
Red Transparent
Green Transparent
Amber Transparent
Smoke Gray Transparent
White Translucent
Notes:
1
2
3
One actuator is located in the center of each multi-pole breaker.
For Switch Only circuits, select Current Coil Rating from the above chart:
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only
circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or
Push-in Stud terminals.
4
5
Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-2
(tin plated).
11
10 LEGEND
4
I - O Vertical
For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power
dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage
= 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper
external resistor limiting current to these values.
1
2
3
No Legend
ON - OFF Vertical
ON - OFF Horizontal
5
6
7
I - O Horizontal
Dual Vertical
6
7
Dual Horizontal
9
11 BEZEL COLOR / STYLE
Color
White
Black
Gray
without Rockerguard
with Rockerguard
8
9
Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent
or match color of LED or neon lamp.
A
B
G
1
2
7
Other colors available. Consult factory.
10 TUV 20A, VDE 15A. UL Recognized and CSAAccepted to 30 amps.
Screw Terminals or Push-in Stud recommended above 20 amps.
11 TUV or VDE Certified must have I-O or Dual Legends.
Legend required on Visi-Rocker breakers.
10
12 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
13 Screw Terminals are VDE certified only with use of ring terminal attached to wire.
14 Terminal code A available with circuit codes A & B only.
12 AGENCY APPROVAL
C
D
E
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
15 Printed circuit board available with UL recognized approval only.
16 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
18
M-Series Circuit Breaker - Rocker UL489A/UL Recognized – Ordering Scheme
M A 1 B 14 620 1 A 1 6 2 J
8
9
10
Legend
11
12
Agency
Approval
1
2
3
4
5
6
7
Illumination Actuator
Color
Bezel Color
Series
Actuator
Poles
Circuit
Frequency
& Delay
Current Rating
Terminal
7 TERMINAL
1 SERIES
11
12
1
2
3
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with Upturned Lugs
Screw 8-32 (Bus Type)
A
P
Push-In Stud
M
Printed Circuit Board
1
2 ACTUATOR
Non-Illuminated
single color
Two Color
Visi-Rocker
illuminated
single color
8 ROCKER ILLUMINATION
Non-illuminated
A
B
Angled
Flat
D
E
Indicate ON
Indicate OFF
F
Angled
Flat
A
G
4
8
Neon
Neon
B
Green Glow
C
Green
G
H
J
without resistor, 120VAC/250VAC
7, 8
LED
Red
D
E
F
Amber
without resistor
K
L
M
with resistor, 4-8 VDC
with resistor, 9-16 VDC
9 ACTUATOR & LEGEND COLOR
Solid Color
Actuator
White
Black
Red
Green
Blue
Yellow
Gray
Orange
Legend
1
Black
White
White
White
White
Black
Black
Black
3 POLES
2
1
One
3
4
5
2
4 CIRCUIT
6
without Auxiliary Switch
7
B
Series Trip (Current)
8
with Auxiliary Switch, Silver Contacts Terminal Type:
6
Visi-Rocker
Visi & Legend (remainder of rocker same color as bezel)
M
S
T
Series Trip (Current) Aux Switch .110 QC x .020 QC
1
White
Black
Red
Green
Blue
3
3,4
3,16
Series Trip (Current)
Series Trip (Current)
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
2
3
U
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
4
with Auxiliary Switch, Gold Contacts
5
3,4
3,16
4
5
9
Series Trip (Current)
Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
Series Trip (Current) Aux Switch .110 QC x .020 QC
.058 Dia, Round Q.C.
6
Yellow
Gray
7
8
Orange
7
Illuminated
Actuator
Legend
White
White
White
White
White
Black
A
B
C
D
E
F
Clear
5 FREQUENCY & DELAY
14
72
74
DC Medium
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
Red Transparent
Green Transparent
Amber Transparent
Smoke Gray Transparent
White Translucent
10
12
DC Instantaneous
DC Short
6 CURRENT RATING (AMPERES)
CODE
AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
10
10 LEGEND
611
711
11.000
11.500
1
2
3
4
5
6
7
No Legend (Single Color or Illuminated Rocker Options Only)
ON - OFF Vertical
ON - OFF Horizontal
I - O Vertical
I - O Horizontal
Dual Vertical
Dual Horizontal
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
8
11 BEZEL COLOR / STYLE
Color
White
Black
Gray
without Rockerguard
with Rockerguard
A
B
G
1
2
7
9
12 AGENCY APPROVAL
Notes:
J
UL489A Listed & TUV Certified
1
2
One actuator is located in the center of each multi-pole breaker.
M
N
T
UL Recognized & CSA Accepted
One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip
& Switch Only circuits, and is not available in single pole illuminated breakers, or with Back
Connected Screw or Push-in Stud terminals.
TUV Certified, UL Recognized & CSA Accepted
UL489A Listed
3
4
5
Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1
(tin plated).
For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum
power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward
voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the
proper external resistor limiting current to these values.
6
7
On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent
or match color of LED or neon lamp.
8
9
Other colors available. Consult factory.
UL Recognized, CSAAccepted, UL489A Listed, and TUV Certified to 30 amps.
Screw Terminals recommended above 20 amps.
10 UL489A Listed must have ON-OFF or Dual legends.
TUV Certified approvals must have I - O or Dual legends.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams |
19
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Schematic shown represents current trip circuit.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
20
M-Series Circuit Breaker - Rocker – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
4
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON.
I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
M-Series Circuit Breaker - Rocker – Supplementary Diagrams |
21
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
22
M-Series, Circuit Breaker - Time Delay Values
,
Notes:
1
2
3
4
Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.
Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle,
8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads.
Dual Rated AC/DC
Instantaneous
Short
Short D2
Medium
Medium D4
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Sales Representatives, Distributors & Company Profile |
23
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 2ꢀ Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 8ꢀ2-2737-2277 Fax: Int + 8ꢀ2-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EXꢀ 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_01_2018